Skip to main content

Plan for a school internet outage before the broadband line fails

The DfE broadband standard asks for a backup connection of a different type that takes over automatically. Keep a printed plan too, and test it at least once a year.

KBY Education 8 min read Sources checked 26 November 2026Schools and trusts
Pale blue fibre optic cables plugged into the ports of a network panel
Photo: Brett Sayles on Pexels

Underlined words are defined in the KBY Lexicon. Tap or click one to see what it means.

When the broadband fails, every school system that runs in the cloud can stop with it. Deciding in advance what staff use instead, and who they ring, helps lessons carry on while it is fixed.

The rules here are based on the Department for Education (DfE) digital and technology standards and its emergency preparedness guidance, read on 26 November 2026. The broadband standard treats internet access as an essential service. It asks schools and colleges to guard against a single point of failure, which is any one part whose loss stops everything.

A second line that takes over on its own

The first protection is a connection that does not depend on the main line. The broadband internet core standard says schools and colleges should have a broadband connection "to ensure resilience and maintain continuity of service". It is one of six core standards that schools should be working towards by 2030.

Its technical requirements ask for a combination of three things:

  • more than one broadband service, each of a different type, such as full fibre (FTTP) combined with low Earth orbit (LEO) satellite
  • more than one router, configured to fail over to the backup automatically when needed
  • backup power options for the core network equipment

The timing is tied to your main line. A backup should go in alongside a new connection, or as soon as possible after it is installed. Your broadband provider can advise on the options and what they cost.

The DfE's comparison of broadband types adds detail on what a good backup does. It should start automatically if the main line fails, and it should be a different type, ideally from a different provider. It should also be able to run essential systems until the main line is fixed.

Mobile broadband and satellite are the backup types that comparison names. It gives 4G an average speed of 24Mbps and 5G an average of 150Mbps. For low Earth orbit (LEO) satellite, the average is between 100 and 200Mbps, with a current maximum of around 500Mbps. Either can be a good backup option, depending on the speeds available at your site.

Installing a backup line does not mean a school meets the broadband standard. It also leaves gaps that only a plan can fill. The emergency preparedness guidance lists "connectivity loss" among its examples of an emergency, and says plans should describe how a setting would keep operating safely during one. The wider set of standards is explained in the guide to the DfE core technology standards.

Mobile phone antennas on a lattice mast against a blue sky with white clouds
Photo: Ulrick Trappschuh on Pexels

Which systems stop when the line does

A backup can fail too. On a secondary school or college site, it may also carry less than the 1Gbps the standard asks of the main line. So the plan starts with what depends on the internet. Cloud solutions are hosted and managed on the internet, and staff reach them through an internet connection. When both lines are down, those services are out of reach from the school site.

Begin with the information the school needs to keep running. Contact details, emails, calendars and essential documents are examples, so find where each one is stored. Then check the services that are easy to forget. The broadband standard gives internet telephony (VoIP) as an example of a cloud-based service. Ask IT support whether your phones depend on the same line.

The backup section of the DfE cyber security standard then asks two useful questions. Which data and systems are critical to function as a school in a disaster? And how long can you go without each one? The answers set the order in which things are recovered. They also feed the disaster recovery plan, which defines a disaster by how long the school can function without its technology.

As a suggestion, one table can hold the answers. Give each system a row with these details:

  • what the system is, and whether it runs in the cloud or on a server in school
  • who supplies it, and how to reach them
  • how long the school can manage without it
  • what staff use instead in the meantime

Suppliers belong in this work as well. The governance standard asks schools to involve outsourced services, such as the management information system (MIS), broadband and cloud providers. Their own protocols for an outage then go into the plan.

A plan you can read when nothing loads

A list kept only in the cloud is no help when the cloud is out of reach. During an incident, your normal ways of communicating may be disrupted, so the contact details have to be somewhere staff can reach them. The governance standard deals with this directly.

Digital technology can go into your existing business continuity and disaster recovery plans, or into a separate plan. Either way, review it every year, or sooner when something significant changes. Then write a short summary with the top-level details, such as key contacts, and share it securely with all staff. The plans and the summary should be printed as hard copies. They should also be kept in a secure shared cloud folder that the disaster recovery team can reach remotely.

The disaster recovery plan itself should name the team and its key contacts. For each person it records who they are, what they are responsible for, and their contact details. It also says how the plan will be tested. Under the cyber security standard, the continuity plan is kept in "at least one or more (diverse) locations". The cloud and a hard copy are the examples given.

Outside contacts need the same care. Your list should include IT support, your cloud providers and your broadband provider. Record what each contract covers, how the supplier can help, and at what point you call them. Check those details every couple of months, because an old number is no use on the day.

The senior leadership team (SLT) member who leads on digital technology is responsible for this standard. The operational team, teaching and admin staff all give input. So do the designated safeguarding lead (DSL), the data protection officer (DPO) and governors or trust leaders, who can sign the plan off.

Printed contact lists hold personal data, so they need the same thought as any other record. The DfE includes paper records among the places a school should look when it lists the personal data it holds. Which details go on paper, who holds a copy, and how old copies are destroyed are for your data protection policy and your DPO.

The lawful basis for each list, and whether a data protection impact assessment (DPIA) is needed, are questions for the DPO. The DfE asks schools to consider a DPIA for data about vulnerable people, children included.

Two red lever arch files standing upright on a wooden surface
Photo: Pixabay on Pexels

On the day the connection drops

With the plan printed, the first hour is about finding out what has failed and telling the right people. Every incident is different, and the aim is to keep disruption to education as small and as short as possible.

A suggested order for the first hour

  1. Ask IT support which services and devices have stopped working.
  2. Note when the problem started, and which parts of the site are affected.
  3. Check whether the backup connection has taken over.
  4. Ring the broadband provider, using the number on the printed contact list.
  5. Tell staff, pupils and parents what has changed, as your emergency plan sets out.
  6. Record what happened and when, for the review afterwards.

Following along on your device? Tap a step’s number to tick it off.

An outage is not always a fault on the line. A denial of service attack, for example, counts as a cyber incident. Other signs of an incident include staff being locked out of their accounts or unable to open documents. Anyone who suspects an attack should report it to IT support and the SLT digital lead.

From that point, the cyber security standard's reporting steps apply. They start with the incident response plan, which forms part of the continuity plans.

The outside contacts come in where a security breach may have happened or other damage was caused. They include your Risk Protection Arrangement (RPA) or cyber insurance provider. Report Fraud, on 0300 123 2040, and the DfE sector cyber team are on the same list. The conditions attached to RPA cover are set out in the guide to RPA cyber cover.

One question is worth settling before an outage rather than during one. The broadband standard expects a content filtering system and a firewall as part of the school's internet service. Ask IT support whether both still apply when traffic moves to the backup line. Any safeguarding judgement about the answer belongs to the DSL, under Keeping children safe in education.

Testing the plan, and when to do it

Testing is how the gaps in a plan show up before a real outage does. The disaster recovery plan should be tested at least once a year, for example by simulating data loss or hardware failure. The emergency preparedness guidance says to use exercises and real incidents to improve plans, and lists testing and reviewing plans among its planning topics.

A tabletop exercise tests the plan without touching the network. The NCSC's free Exercise in a Box includes tabletop exercises, which are group discussions of an incident as it unfolds. Backups need their own checks, because the cyber standard asks for them to be tested and logged every term.

As a suggestion, the backup connection can be tested too, by asking IT support to disconnect the main line and watch the failover.

Warning

Disconnecting the main line can stop lessons and phones if the failover does not work. Test out of hours or in a school holiday, never in exam season. Agree first how IT support will reconnect the main line, and keep the provider's number to hand.

After any test or real outage, write down what went wrong and change the plan. After a crisis, the emergency guidance asks for an evaluation, with the lessons fed into future planning. Then reprint the summary, replace the old copies, and report the changes to governors or trustees.

Common questions

Does a school have to have a backup broadband connection?
The DfE broadband core standard says schools and colleges should have one, and schools should be working towards the core standards by 2030. The backup should go in alongside a new main connection, or as soon as possible after it.
Is 4G or 5G mobile broadband enough as a backup?
The DfE's comparison of broadband types gives 4G an average of 24Mbps and 5G an average of 150Mbps, and says mobile broadband can be a good backup depending on the speeds available. A backup should also start automatically and be a different type from the main line.
How often should a school test its continuity plan?
The DfE governance standard says the disaster recovery plan should be tested at least once a year, and the plans reviewed every year or when something significant changes. Backups should be tested and logged every term.

Sources

Every requirement, licence detail and figure in this guide comes from these pages, read on 26 November 2026. Guidance, licences and products change: check the source before you rely on one.

  1. Meeting digital and technology standards in schools and colleges: Broadband internet: core standard, Page shows updated 16 September 2026 (Department for Education)
  2. Compare types of broadband for schools and colleges (Department for Education (Plan technology for your school))
  3. Meeting digital and technology standards in schools and colleges: Digital leadership and governance: core standard, Last updated 16 September 2026 (Department for Education)
  4. Meeting digital and technology standards in schools and colleges: Cyber security: core standard, Last updated 16 September 2026 (Department for Education)
  5. Meeting digital and technology standards in schools and colleges: Cloud solutions, Last updated 16 September 2026 (Department for Education)
  6. Emergency preparedness, response and recovery, Last updated 26 November 2026 (Department for Education)
  7. Data protection in schools: Data protection policies and procedures, Last updated 25 November 2026 (Department for Education)
  8. Small Business Guide: Response & Recovery, Published 12 June 2019, reviewed 8 October 2020 (NCSC)
  9. Small Business Guide: Response & Recovery, Step 1: Prepare for incidents, Published 10 June 2019, reviewed 8 October 2020 (NCSC)
  10. Small Business Guide: Response & Recovery, Step 2: Identify what's happening, Published 10 June 2019, reviewed 8 October 2020 (NCSC)
  11. Exercise in a Box (NCSC)

Spotted something wrong or out of date? Tell us and we will correct it.

About this page

Credited to

Dates

Published

Corrections

No corrections are listed for this page. Some review sweeps corrected pages without naming each one; those are in the corrections log.

Keep reading

More education guides

All education guides

Recommended reading

Share this guideXLinkedInFacebookEmail

Was this useful?

Reports go to the site owner and are used to correct pages. Corrections are listed at /corrections.

All education guides

KBY Weekly

A short email every Saturday morning with the week's tech tips, fixes and scam alerts for your phone, laptop, home Wi-Fi, camera and more, in plain English.